Corrosion & Scale Inhibitors

Closed circuit heating and cooling systems must be well maintained to operate at optimum efficiency so it is essential that the correct water conditions are maintained at all times. This can be achieved using carefully selected inhibitors designed to control corrosion, scale/fouling and maintain flow and heat transfer. Our advanced KOOL LOOP closed circuit inhibitors have been scientifically formulated to protect closed systems including closed chilled water, low, medium and high temperature/pressure heating systems from the effects of both metallic corrosion and fouling all within in a single product. ChemREADY’s scale & corrosion inhibitors deliver improved performance, helping to reduce maintenance costs, improve reliability and optimize operational efficiency.

If you’re ready to treat your system with KL 210, click below for pricing, dosing, and technical information

Request Info
  • High performance corrosion inhibitor and antifoulant
  • Suitable for both closed chilled water
  • Effective protection over a range of metals
  • Innovative blends of organic and inorganic corrosion inhibitors including molybdate
  • Effective protection over a range of metals
  • Low eco-toxicity

FAQ for Kool Loop MN-605

What is KL MN-605?

KL MN-605 is a liquid scale and corrosion inhibitor specifically designed for use in recirculating, nonpotable hot and chill water systems. It offers robust protection against corrosion and scale formation for metals commonly found in these systems, such as steel, brass, bronze, and copper.

How does KL MN-605 work?

KL MN-605 utilizes a blend of corrosion inhibitors and synthetic polymer dispersants to prevent scale formation and protect metals from corrosion. It also has the ability to redissolve and disperse existing deposits, ensuring the cleanup of previously fouled systems.

What types of systems is KL MN-605 suitable for?

Kool Loop MN-605 is suitable for use in recirculating, nonpotable hot and chilled water systems. It is particularly effective in systems with high copper content and those utilizing biocides.

What are the dosage rates for KL MN-605?

The recommended dosage rate for Kool Loop MN-605 is 1 quart per 50 to 100 gallons of water in the system. This dosage maintains a residual of 100-200 ppm of Molybdenum. Dosages may need to be adjusted based on the system’s makeup water volume and the corrosivity of the water.

How is KL MN-605 applied?

Kool Loop MN-605 can be applied manually using a bypass-type feeder for systems with lower makeup water requirements. For systems with large makeup water needs or high corrosivity, it is advisable to feed MN-605 automatically using a chemical feed pump on a continuous or intermittent basis.

Product Application Use Industry Use
Kool Loop MN-605

Liquid scale and corrosion inhibitor designed for use in recirculating, nonpotable hot and chill water systems with high copper content and oxidizing biocide programs

Kool Loop MN-605 offers robust protection for steel, brass, bronze, copper, and other metals commonly found in such water systems. It utilizes a blend of corrosion inhibitors to ensure comprehensive multimetal corrosion protection.

closed cooling water system
Closed Loop Water Treatment