Water Facts Blog
Water Facts
ST108

ST108 Installation and Qualification Testing

Welcome to Step 7 of the ST108 Implementation Timeline: ST108 Installation and Qualification Testing. This step is critical for achieving and maintaining high water quality standards in medical device processing.

Installation Qualification for ST108 Installation and Qualification Testing

To begin, create a detailed installation plan that outlines the system layout, piping, and connections. Anticipate potential challenges and ensure easy access for future maintenance. It’s essential to work with contractors experienced in both water treatment systems and medical device environments to ensure the system is installed properly.

Once installation is complete, you need to verify that every aspect of the system meets the original design specifications and manufacturer guidelines. This includes inspections to ensure operational reliability and long-term system performance.

Operational Qualification for ST108 Installation and Qualification Testing

After installation, the next step is Operational Qualification, where the system is tested under normal operating conditions. This involves monitoring key parameters like flow rates, pressure, and water quality to ensure the system is functioning as expected. Regular testing during this stage helps identify any issues that might not have been apparent during installation.

In addition to testing, developing standard operating procedures (SOPs) for system operation, maintenance, and troubleshooting is crucial. These procedures provide the team with step-by-step guidance, ensuring consistency and safety in system management. Proper training is critical here as well—ensure that all personnel involved in water treatment undergo comprehensive training and participate in regular competency checks.

Performance Qualification

Once Operational Qualification is complete, you’ll move on to Performance Qualification. This is an ongoing phase where you continuously validate that the system produces water that meets all necessary quality standards under normal conditions. During this phase, regular monitoring and testing of key water quality parameters help identify any deviations and allow for prompt corrective action.

Continuous improvement is also essential in this phase. Regularly tracking performance data, documenting corrective actions, and making adjustments ensures the system remains efficient and compliant with ST108 standards. Maintaining thorough records of equipment, water quality tests, maintenance activities, and system adjustments supports this ongoing improvement and provides a clear audit trail for compliance reviews.

The steps outlined in the ST108 Implementation Timeline are crucial to ensuring your water treatment system is installed, tested, and optimized for long-term, high-quality performance. By following a structured approach to installation, operational testing, and continuous performance validation, your system will not only meet industry standards but will also operate efficiently and reliably. Proper documentation, ongoing monitoring, and a commitment to continuous improvement are key to maintaining water quality in medical device processing environments.

Thanks for following along! Stay tuned for the next steps in our ST108 Implementation series. For more information or if you have any questions, feel free to reach out to us at ChemREADY.

Learn more about our Water Treatment Services and Chemical Products

Contact Us